Signs and Outdoor Display Structures in UDCPR 2020

Apr 07, 2024

UDCPR 2020 Chapter 12 is all about the Structural Safety, Water supply, Drainage, and Sanitary Requirements, Outdoor Display, And Other Services in Development Plans as per mentioned in the UDCPR 

 

This is Applicable to all Planning Authorities and Regional Plan Areas except Municipal Corporation of Greater Mumbai, Other Planning Authorities/Special Planning Authorities/ Development Authorities within the limit of Municipal Corporation of Greater Mumbai, MIDC, NAINA, Jawaharlal Nehru Port Trust, Hill Station Municipal Councils, Eco-sensitive/Eco-fragile region notified by MoEF & CC and Lonavala Municipal Council, in Maharashtra.

 

Rule No. 12.7 Signs and Outdoor Display Structures

 

12.7.1  

 

The display of advertising signs on buildings and land, shall be in accordance with Part - 10, Section 2 "Signs and outdoor display structures" of the National Building Code of India as amended from time to time and, shall be in accordance with respective rules/by-laws, directive given by Government, and also rules/by-laws framed by the Authority in this regards from time to time.

 

12.7.2  Prohibition of advertising signs and outdoor display structure in certain cases

 

Notwithstanding the provisions of sub-regulations, no advertising sign or outdoor display structures shall be permitted on buildings of architectural, aesthetical, historical, or heritage importance as may be decided by the Authority or on Government Buildings save that in the case of Government buildings only advertising signs or outdoor display structure may be permitted if they relate to the activities for the said buildings’ own purposes or related programmers.

 

Table No.12-C : Sanitation Requirements - Office Buildings

Sr. No.FixturesPublic ToiletsStaff Toilets
  MaleFemaleMaleFemale
(1)(2)(3)(4)(5)(6)
i)

Executive Rooms and Conference Halls in Office Buildings

Toilet suite comprising one WC, one washbasin (with optional shower stall if the building is used round the clock at user’s option)

 

Pantry optional as per user requirement

The unit could be common for Males/Females or separate depending on the number of users of each facilityFor individual officer rooms
ii) Main Office Toilets for Staff and Visitors
 a) Water-closet1 per 251 per 151 per 251 per 15
 b) Urinals

Nil up to 6 1 for 7-20 2 for 21-45 3 for 46-70

4 for 71-100

 

Nil up to 6 1 for 7-20 2 for 21-45 3 for 46-70

4 for 71-100

 
 Add @ 3% for101-200 101-200 
 Add @ 2.5 %Over 200 Over 200 

 

Table No.12-D : Sanitation Requirements – Factories

Sr. No.FixturesOffices / VisitorsWorkers
MaleFemaleMaleFemale
(1)(2)(3)(4)(5)(6)
i)Water Closets (Workers & Staf1 for up to 25 2 for 16-35
3 for 36-65
4 for 66-10

1 for up to 15 2 for 16-25
3 for 26-40
4 for 41-57

5 for 58-77 6 for 78-100

1 for up to 15
2 for 16-35
3 for 36-65

4 for 66-10

1 for up to 12 and 2 for 13-25
3 for 26-40
4 for 41-57

5 for 58-77

 For persons 101 - 200 add3%5%3%5%
 For persons over 200 add2.5 %4%2.5 %4%
ii)Urinals

Nil up to 6

1 for 7-20
2 for 21-45 

3 for 46-70

4 for 71-100

-

Nil up to 6 

1 for 7-20
2 for 21-45 

3 for 46-70 

4 for 71-100

-
 For persons 101 - 200 add3%5%3%5%
 For persons over 200 add2.5%4%2.5%4%

 

Table No.12-E : Sanitation Requirements - Cinema, Multiplex Cinema, Concerts and Convention Halls, Theatres

Sr. NoFixturesPublicStaff
MaleFemaleMaleFemale
(1)(2)(3)(4)(5)(6)
i)Water-closets1 per 100 up to 400 Over 400, add at 1 per 250 or part thereof3 per 100 up to 200 Over 200, add at 2 per 100 or part thereof1 for up to 15 2 for 16-351 for up to 12
2 for 13-25
ii)Urinals1 per 25 or part thereof-Nil up to 6 1 for 7-20 2 for 21-45-
NOTE - The male population may be assumed as two-thirds and the two-thirds female population as one-third.

 

Table No.12-F- Sanitation Requirements - Art Galleries, Libraries and Museums

Sr. No.FixturesPublicStaff
MaleFemaleMaleFemale
(1)(2)(3)(4)(5)(6)
i)Water-closets

1 per 200 up to 400

Over 400 add at 1 per 250 or part thereof

1 per 100 up to 200

Over 200 add at 1 per 150 or part thereof

1 for up to 15 2 for 16-351 for up to 12 and 2 for 13-25
ii)Urinals1 per 50-Nil up to 6 1 per 7-20 2 per 21-45-
Notes - The male population may be assumed as two-third and the female population as one-third.

 

Table No.12-G Sanitation Requirements - Hospitals with Indoor Patient Wards

Sr. No.FixturesPatient ToiletsStaff Toilets
MaleFemaleMaleFemale
(1)(2)(3)(4)(5)(6)
i)Toilet suite comprising one WC The male two-thirds one washbasin and shower stallPrivate room with up to 4 patientsFor individual doctor’s/officer’s rooms
For General Wards, Hospital Staff and Visitors
ii)Water-closets1 per 8 beds or part thereof1 per 8 beds or part thereof1 for up to 15 2 for 16-351 for up to 12 2 for 13-25
iii)Urinals1 per 30 beds-Nil up to 6 1 for 7 to 20-
Note - Male population may be assumed as two-thirds and the female population as one-third.

 

Table No.12-H Sanitation Requirements - Hospitals - Outdoor Patient Department

Sr. NoFixturesPatient ToiletsStaff Toilets
MaleFemaleMaleFemale
(1)(2)(3)(4)(5)(6)
i)Toilet suite comprising one WC and one washbasin (with optional shower stall if building used for 24 h)For up to 4 patientsFor individual doctor’s / officer’s rooms
ii)Water-closets1 per 100 persons or part thereof2 per 100 persons or part thereof1 for up to 15 2 for 16-351 for up to 12
2 for 13-25
iii)Urinals1 per 50 persons or part thereof-Nil up to 6 1 per 7 to 20 2 per 21-45-
Note - The male population may be assumed as two-third and the female population as one-third.

 

Table No.12-I Sanitation Requirements - Hospitals’ Administrative Buildings

Sr. NoFixturesStaff Toilets
MaleFemale
(1)(2)(3)(4)
i)Toilet suite comprising one WC and one washbasin (with optional shower stall if building used for 24 h)For individual doctor’s/officer’s rooms
ii)Water-closets1 per 25 persons or part thereof1 per 15 persons or part thereof
iii)UrinalsNil up to 6 1 per 7 to 20 2 per 21-45 
Note - Some WCs may be European style if desired.

 

Table No.12-J Sanitation Requirements - Hospitals’ Staff Quarters and Nurses Homes

Sr. NoFixturesStaff QuartersNurses Homes
MaleFemaleMaleFemale
(1)(2)(3)(4)(5)(6)
i)Water-closets1 per 4 persons or part thereof1 per 4 persons or part thereof1 per 4 persons or part thereof
2 for 16-35
1 per 4 persons or part thereof
2 for 16-35

 

Table No.12-K Sanitation Requirements - Hotels

Sr. No.FixturesPublic RoomsNon-Residential Staff
MaleFemaleMaleFemale
(1)(2)(3)(4)(5)(6)
i)Toilet suite comprising one WC, washbasin with shower or a bathtubIndividual guest rooms with attached toilets-
Guest Rooms with Common Facilities
ii)Water-closets1 per 100 persons up to 400
Over 400 add at 1 per 250 or part thereof
2 per 100 persons up to 200
Over 200 add at 1 per 100 or part thereof
1 for up to 15 2 for 16-35
3 for 36-65
4 for 66-100

1 for up to 12
2 for 13-25
3 for 26-40

4 for 41-57 5 for 58-77 6 for 78-100

iii)Urinals1 per 50 persons or part thereofNil, up to 6 persons: 1 for 7-20 persons 2 for 21-45 persons 3 for 46-70 persons 4 for 71-100 personsNil up to 6 1 for 7 to 20 2 for 21-45 3 for 46-70 4 for 71-100-
Note - The male population may be assumed to be the male two-thirds and the female population as one-third.

 

Table No.12-L Sanitation Requirements – Restaurants

Sr. No.FixturesPublic RoomsNon-Residential Staff
MaleFemaleMaleFemale
(1)(2)(3)(4)(5)(6)
i)Water Closets1 per 50 seats up to 200 Over 200 add at 1 per 100 or part thereof2 per 50 seats up to 200
Over 200 add at 1 per 100 or part thereof
1 for up to 15 2 for 16-35
3 for 36-65
4 for 66-100

1 for up to 12 

2 for 13-25
3 for 26-40
4 for 41-57

5 for 58-77 6 for 78-100

ii)Urinals1 per 50 persons or part thereof--Nil up to 6 1 for 7-20
2 for 21-45 3 for 46-70 4 for 71-100
--
NOTE : The male population may be assumed as two-thirds and the female population as one-third.

 

Table No.12-M Sanitation Requirements – Schools and Educational Institutions

Sr.NoFixturesNursery SchoolNon-ResidentialResidential
 BoysGirlsBoysGirls
(1)(2)(3)(4)(5)(6)(7)
i)Water Closets1 per 15 pupils or part thereof1 for 40 pupils or part thereof1 per 25 pupils or part thereof1 per 8 pupils or part thereof1 per 6 pupils or part thereof
ii)Urinals--1 per 20 pupils or part thereof--1 per 25 pupils or part thereof--

 

Table No.12-N Sanitation Requirements – Hostels

Sr. No.FixturesResidentNon-ResidentVisitor / Common Rooms
MaleFemaleMaleFemaleMaleFemale
(1)(2)(3)(4)(5)(6)(7)(8)
i)Water Closet1 per 8 or part thereof1 per 6 or part thereof

1 for up to 15 

2 for 16-35
3 for 36-65
4 for 66-100

1 for up to 12 

2 for 13-25
3 for 26-40
4 for 41-57

5 for 58-77 

6 for 78-100

1 per 100 up to 400

Over 400 add at 1 per 250

1 per 200 up to 200

Over 200 add at 1 per 100

ii)Urinals1 per 25 or part thereof--

Nil up to 6 

1 for 7-20
2 for 21-45 3 for 46-70 4 for 71-100

--1 per 50 or part thereof--

 

Table No.12-O Sanitation Requirements – Mercantile Buildings, Commercial Complexes, Shopping Malls, Fruit & Vegetable Markets

Sr. No.FixturesShop OwnersCommon Toilets in Market / Mall BuildingPublic Toilet for Floating Population
MaleFemaleMaleFemaleMaleFemale
(1)(2)(3)(4)(5)(6)(7)(8)
i)Water Closets1 per 8 persons or part thereof

1 for up to 15 

2 for 16-35
3 for 36-65
4 for 66-100

1 for up to 12 

2 for 13-25
3 for 26-40
4 for 41-57

5 for 58-77 

6 for 78-100

1 per 50 (Minimum 2)1 per 50 (Minimum 2)
ii)Urinals----

Nil up to 6 

1 for 7-20
2 for 21-45 

3 for 46-70 

4 for 71-100

--1 per 50--

 

Table No.12-PSanitation Requirements – Airports and Railway Stations

Sr. No.FixturesJunction Stations, Intermediate Stations and Bus StationsTerminal Railway and Bus StationsDomestic and International Airports
MaleFemaleMaleFemaleMaleFemale
(1)(2)(3)(4)(5)(6)(7)(8)
i)Water- closet3 for up to 1000 Add 1 per additional 1000 or part thereof4 for up to 1000 Add 1 per additional 1000 or part thereof4 for up to 1000 Add 1 per additional 1000 or part thereof5 for up to 1000 Add 1 per additional 1000 or part thereof

Minimum - 2 

for 200 - 2 

For 400 - 9 

For 600 - 12 

For 800 - 16

Minimum - 2 

For 200 - 2 

For 400 - 9 

For 600 - 12 

For 800 - 16 

For 1000 - 18

ii)Urinals4 for up to 1000. Add 1 per additional 1000--6 for up to 1000. Add 1 per additional 1000--1 per 40 or part thereof--
iii)Toilet for Disabled1 per 40001 per 40001 per 40001 per 40001 per 4000 (Minimum 1)1 per 4000 (Minimum 1)

 

Related Regulations

 

You can visit our other blogs related to Regulations 12 through the below-mentioned links

 

Drainage and Sanitation Requirements in UDCPR 2020

 

Water Supply, Drainage, and Sanitary Requirements in UDCPR 2020

 

Alternatives Materials, Methods of Design & Construction, and Tests in UDCPR 2020

 

Building Services in UDCPR 2020

 

Quality of Materials and Workmanship in UDCPR 2020

 

Structural Safety, Water Supply, Drainage and Sanitary Requirements, Outdoor Display, and Other Services in UDCPR 2020